Catering & laundry equipment



DRY CLEANING MACHINES

MEC Vantage Range

Dry Cleaning

The dry cleaning process is suitable for cleaning fabric and leather garments using organic solvents. Perchloroethylene (tetrachlorethylene C2 CL4) is the most widely used solvent in the dry cleaning industry world-wide; it offers high cleaning power and is compatible with most natural and synthetic fibres. In addition, it is ideal for industrial cleaning applications, especially where garments are heavily soiled with grease based soils.

Dry Clean With PERC

ILSA machines use state-of-the-art technology to ensure low emissions and operator safety while offering great versatility and superior performance.

DESCRIPTION / MODEL   240 320 380 440 500 640
Loading Capacity (1:20) kg 12 16 19 22 25 32
Loading Capacity (1:18) kg 14 18 21 24 28 35
Drum
Volume litres 240 320 380 440 500 640
Diameter mm 900 900 1000 1000 1100 1100
Depth mm 390 500 480 560 530 670
Loading Door Diameter mm 500 500 500 500 500 500
Drum Revolutions
Clean Std minØ1 43 43 35 35 29 29
Extraction Max minØ1 436 436 420 420 400 400
Useful Tank Volume
Tank 1 litres 130 130 200 200 275 275
Tank 2 litres 130 130 200 200 275 275
Tank 3 litres 160 160 260 260 260 260
Distilator
Working Volume Still litres 135 135 240 240 365 365
Distillation Capacity
Still Capacity (steam model) litres/hr 130 130 290 290 400 400
Still Capacity (electric model) litres/hr 60 70 120 120    
Filter
Spin Filter pz. 2 2 2 2 2 2
Filter Volume litres 50 50 75 75 90 90
Filtering Surface mq 3,36x2 3,36x2 4,96x2 4,96x2 6,24x2 6,24x2
Solvent Load
Load litres 520 520 810 810 990 990
Load kg 842 842 1312 1312 1604 1604
Dimensions
Width mm 1820 1820 2515 2515 2690 2690
Depth mm 2000 2000 2000 2000 2200 2200
Height mm 2390 2390 2450 2450 2625 2625
Height for Entry mm 2060 2060 2095 2095 2165 2165
Weight/Ground Load
Empty Weight kg 2430 2490 2640 2670 3090 3170
Static kg/mq 783 803 778 787 778 787
Static and Dynamic kg/mq 956 1034 1039 1089 1039 1089
Electrical Power
Solvent Pump kW 0.56 0.56 1.1 1.1 1.1 1.1
Fan kW 2.2 2.2 0.75 0.75 0.75 0.75
Cooling Compressor kW 4,94 4,94 4,94 4,94 4,94 4,94
Motor With Inverter kW 2.2 2.2 4 4 5.5 5.5
Spin Filter Motor kW 0,55x2 0,55x2 0,55x2 0,55x2 0,55x2 0,55x2
Air Compressor (opt.) kW 0.37 0.37        
Electric Model
Distillation Boiler kW 7.5 7.5 15 15    
Drying Boiler kW 9 9 10.5 10.5    
Connections
Steam Model A 16 16 17 17 25 25
Electric Model A 43 43 59 59    
Electric 3x400 V3/N/PEØ50Hz
Steam 1/2” Ø4,5 bar Ø150°C max
Water 3/4” Ø3,5 bar Ø25°C max
Compressed Air 1/4” Ø6 bar